CBSHM - K-5200-K MIRACLE POWER DGF 123 (CFC-FREE)

  • MSDS: CBSHM
  • Manufacturer: MIRACLE POWER PRODUCTS CORP
  • Product Name: K-5200-K MIRACLE POWER DGF 123 (CFC-FREE)
  • National Stock Number: 9150-01-170-1567
Product Identification

Product ID:K-5200-K MIRACLE POWER DGF 123 (CFC-FREE)
MSDS Date:05/23/1995
FSC:9150
NIIN:01-170-1567
MSDS Number: CBSHM

Responsible Party
MIRACLE POWER PRODUCTS CORP
1101 BELT LINE ST
CLEVELAND, OH 44109-2819
US

Emergency Phone: 216-741-1388

Info Phone: 216-741-1388

Preparer: S. VANDIVORT

Cage: 16837

Contractor
MIRACLE POWER PRODUCTS CORP
CLEVELAND, OH 44109 US

Telephone: 216-741-1388

Cage: 16837

Ingredients

PROPANE (INGREDIENT 1 & 2 COMBINED MAKE UP 35-45%)

CAS: 74-98-6

RTECS: TX2275000

Fraction By Weight: 35-45%

OSHA PEL 1000 PPM

ACGIH TLV: ASPHYXIANT; 9596


ISOBUTANE (INGREDIENT 1 & 2 MAKE UP 35-45%) (PROPELLANT)

CAS: 75-28-5

RTECS: TZ4300000

Fraction By Weight: 35-45%


ACETONE (SARA 313) (CERCLA)

CAS: 67-64-1

RTECS: AL3150000

Fraction By Weight: 40-50%

OSHA PEL 1000 PPM

ACGIH TLV: 750PPM/1000STEL;9596

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


N-BUTYL ALCOHOL (SARA 313) (CERCLA)

CAS: 71-36-3

RTECS: EO1400000

Fraction By Weight: <2%

OSHA PEL 100 PPM

ACGIH TLV: S, C 50 PPM; 9596

EPA Report Quantity: 5000 LBS

DOT Report Quantity: 5000 LBS


GRAPHITE, NATURAL (SOLID LUBRICANT)

CAS: 7782-42-5

RTECS: MD9659600

Fraction By Weight: 1-3%

OSHA PEL 15 MPPCF; Z-3

ACGIH TLV: 2 MG/M3 RDUST; 9596

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:YES Ingestion:YES
Reports of Carcinogenicity:NTP:NO IARC:NO OSHA:NO
Health Hazards Acute and Chronic:ACUTE: INHALATION MAY CAUSE
NASAL/RESPIRATORY IRRITATION AND CNS DEPRESSION. CONTACT MAY CAUSE
SKIN AND EYE IRRITATION. INGESTION MAY CAUSE GI TRACT IRRITATION.
CHRONIC: PROLONGED OR REPEATED EXPOSURE MAY CAUSE SKIN DEFATTING
AND DERMATITIS.
Explanation of Carcinogenicity:NO INGREDIENT OF A CONCENTRATION OF 0.1%
OR GREATER IS LISTED AS A CARCINOGEN OR SUSPECTED CARCINOGEN.
Effects of Overexposure:INHALED-HEADACHE, DIZZINESS, NAUSEA, FATIGUE,
NASAL & RESPIRATORY IRRITATION. EYES-REDNESS, TEARING, BLURRED
VISION. SKIN-IRRITATION, DEFASTTING, DERMATITIS. INGESTED-NAUSEA,
VOMITING, DIARRHEA.
Medical Cond Aggravated by Exposure:NOT DETERMINED; HOWEVER, PERSONS
WITH CHRONIC RESPIRATORY DISEASE MAY SHOW INCREASED SYMPTOMS DUE TO
IRRITATION.

First Aid

First Aid:EYES-FLUSH WITH WATER FOR 15 MINUTES, LIFT LIDS. GET MEDICAL
ATTENTION. SKIN-LAUNDER CONTAMINATED CLOTHES. WASH SKIN WITH MILD
SOAP & WATER. INHALED-REMOVE TO FRESH AIR. APPLY ARTIFICIAL
RESPIRATION I F NEEDED. KEEP PERSON WARM & DRY. GET MEDICAL HELP.
INGESTED-KEEP HEAD DOWN. CONTACT POISON CONTROL CENTER OR PHYSICIAN
AND OBTAIN IMMEDIATE MEDICAL ATTENTION.

Fire Fighting

Flash Point:<0F,<-18C
Lower Limits:1.8
Upper Limits:13
Extinguishing Media:CARBON DIOXIDE, DRY CHEMICAL, FOAM. WATER TO COOL
EXPOSED CONTAINERS MAY BE HELPFUL.
Fire Fighting Procedures:WEAR SELF-CONTAINED BREATHING APPARATUS AND
FULL FIRE FIGHTER'S PROTECTIVE GEAR.
Unusual Fire/Explosion Hazard:AT ELEVATED TEMPERATURES (OVER 130F)
AEROSOL CONTAINERS MAY BURST, VENT OR RUPTURE. USE EQUIPMENT OR
SHIELDING TO PROTECT PERSONNEL FROM RUPTURING CONTAINERS.

Accidental Release

Spill Release Procedures:ELIMINATE ALL SOURCES OF IGNITION. VENTILATE
AREA. USE PROTECTIVE EQUIPEMNT CONSISTENT WITH THE SITUATION.
GATHER SPILL ON ABSORBENT MATERIAL AND PLACE IN TO METAL CONTAINER
FOR DISPOSAL.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE IN A COOL, DRY PLACE OUT OF
DIRECT SUNLIGHT. DO NOT PUNCTURE, INCINERATE (BURN) OR HEAT ABOVE
130F EITHER FULL OR EMPTY CONTAINERS.
Other Precautions:STORE AWAY FROM INCOMPATIBLE MATERIALS. DO NOT REMOVE
OR DEFACE LABEL. PLEASE READ AND FOLLOW DIRECTIONS ON PRODUCT LABEL
OR ANY ACCOMPANYING LITERATURE. DO NOT USE IN CONFINED OR ENCLOSED
SPACE, VENT ILATION SHOULD MAINTAIN EXPOSURE

Exposure Controls

Respiratory Protection:NONE NORMALLY REQUIRED. IF ENGINEERING CONTROLS
FAIL OR NON-ROUTINE USE OR AN EMERGENCY OCCURS; WEAR AN MSHA/NIOSH
APPROVED RESPIRATOR WITH ORGANIC VAPOR CARTRIDGE OR AN AIR-SUPPLIED
RESPIRATOR OR SCB A, AS REQUIRED. USE IAW 29 CFR 1910.134.
Ventilation:USE ADEQUATE MECHANICAL VENTILATION, LOCAL EXHAUST OR
SPEACIAL VENTILATION TO MAINTAIN EXPOSURE BELOW TLV(S).
Protective Gloves:BUTYL, NITRILE.
Eye Protection:SAFETY GLASSES/CHEMICAL SPLASH GOGGLES.
Other Protective Equipment:AS REQUIRED BY LOCAL STANDARD OPERATIONG
PROCEDURES. DLA-HMIS: EYE WASH STATION & SAFETY SHOWER.
Work Hygienic Practices:WASH HANDS AFTER HANDLING AND BEFORE EATING,
DRINKING, OR SMOKING. LAUNDER CONTAMINATED CLOTHES BEFORE REUSE.
Supplemental Safety and Health

Chemical Properties

HCC:V3
Vapor Pres:2069
Vapor Density:>1
Spec Gravity:<1
Evaporation Rate & Reference:<1 (ETHER=1)
Solubility in Water:APPRECIABLE
Appearance and Odor:GREY-BLACK MIST W/KETONE ODOR DISPENSED FROM
AEROSOL PACKAGE.
Percent Volatiles by Volume:>95

Stability

Stability Indicator/Materials to Avoid:YES
STRONG OXIDIZING AGENTS, STRONG ALKALIS, STRONG MINERAL ACIDS.
Stability Condition to Avoid:AVOID HEAT SUFFICIENT TO BURST CAN &
SPRAYING INTO FLAME OR ONTO HOT SURFACES WHICH MAY CAUSE
DECOMPOSITION.
Hazardous Decomposition Products:NOT DETERMINED,HOWEVERE WE EXPECT
CARBON MONOXIDE & CARBON DIOXIDE,VARIOUS IMCOMPLETELY BURNED
PRODUCTS,POSSIBLY TOXIC.

Disposal

Waste Disposal Methods:DO NOT PUNCTURE OR INCINERATE CONTAINERS. GIVE
EMPTY, LEAKING OR FULL CONTAINERS TO A DISPOSAL SERVICE EQUIPPED TO
SAFELY HANDLE AND DISPOSE OF PRESSURIZED CONTAINERS. CONSULT LOCAL,
STATE, AND FEDERA L REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.